Find the right measurement.

Compare the measurements, integration requirements and published specifications. Tools are supplied with field personnel; the package follows the well.

90°per bin4 physical detectors
2 / 4 / 8azimuthal bins

Give gamma a direction.

Change the bin count to see how the azimuthal response is grouped around the borehole. Four physical detectors serve every setting.

4 windows of 90°

Technical context & source

Conceptual cross-section, not a measured gamma image. Confirm sampling, rotation limits and surface decoding for the selected configuration.

Open original brochure

Compare the measurement systems.

A comparison for initial screening. Use each system’s specifications and the selected assembly limits for the technical review.

SystemMeasurementPublished referenceConfirm for the job
Near-Bit MeasurementInclination, azimuth, gamma and azimuthal gamma near the bit12 in sensor offset
175°C
EM short-hop conditions, receiver, connections and the complete BHA envelope
Quad OrbitalAzimuthal gamma with up/down gamma in slides2 / 4 / 8 bins
175°C · 100 rpm
Compatible MWD string, PDT surface decoding and sampling configuration
OmegaPhase and attenuation propagation resistivity400 kHz / 2 MHz
150°C
Collar, electrical interface and formation-dependent investigation depth
APWDAnnular pressure, temperature and drilling dynamics1 psi repeatability
175°C
Selected transducer range, system pressure limit and real-time channels

Sources: supplied MWD Solutions product brochures. Ratings apply to the stated component and configuration; they are not a system-wide guarantee. Scroll the table horizontally on smaller screens.

Telemetry is part of the application review.

MWD Solutions discusses EM, mud-pulse and dual-telemetry configurations alongside the measurement package.

Review the formation, depth, mud system, surface conditions and real-time data priorities. The near-bit EM short-hop is a separate link inside the assembly; it does not replace surface telemetry.

Confirm the selected platform, decoder, transmitted channels, update requirements and memory-data handoff before the run.

Review the technical workflow
MWD Solutions published artwork: Specify the information, not just the transmission rate.
Published November 3, 2026. Original LinkedIn post

Specify the information, not just the transmission rate.

As ROP increases, a fixed update frequency gives fewer valid measurements per foot. Review the sampling requirements, channel priorities and decoding quality together. The useful question is what information reaches the team at the depth where a decision is needed.

Read the original perspective

Bring the well requirements.

Bring the well objective, expected conditions and the measurements you need. We’ll work through tool selection and field-personnel scope with you.

Talk with Corey